Gravity in calculations: near Earth, g ≈ 9.8 m/s² (9.8 N/kg). Use the value supplied by the question, page instructions or activity; use 10 when it is specified.
Track what changes, label field–current–motion–force directions, read the coil position, then let ratios and squared-current loss finish the calculation.
Induction & fieldsGenerator & motorTransformer ratiosLow-voltage ATP
Classify the trigger first; the correct law and direction rule then become much easier to see.
2
Change of linkage is the cause
Electromagnetic induction
Induction requires a conductor moving across a field or a changing field linking a coil.
A stationary magnet and stationary coil do not maintain induced e.m.f. Stronger fields, faster change and more coil turns can increase induced e.m.f. Current needs a closed circuit; an open circuit can still have e.m.f.
Approach: the centre-zero meter deflects while linkage changes.Hold still: the pointer returns to zero even with the magnet inside the coil.Withdraw: the change reverses, so the induced polarity reverses.Faster change, more turns and a stronger field increase the magnitude of the induced e.m.f.
Induced e.m.f. exists when magnetic linkage changes. Magnitude depends on how rapidly the linkage changes; direction depends on the direction of that change.
Look for relative motion or a changing magnetic field.
Decide whether linkage is increasing, decreasing or constant.
Use speed, turns and field strength only for size.
For direction, work out which induced effect would oppose the change.
Interactive · Induction response
Build the peak meter response
Change
Magnitude
Polarity
move faster
larger
unchanged if motion direction is unchanged
more turns
larger
unchanged
stronger magnet
larger
unchanged
reverse motion or pole
same if conditions match
reversed
Magnitude mnemonicS · T · F = SPEED · TURNS · FIELD
Ask “how fast?”, “how many links?” and “how strong?”.
Full-mark explanation: “The magnetic field linking the coil changes more rapidly, so a larger e.m.f. is induced.” State the changing quantity—not merely “the magnet moves”.
Quick Check · What does each part of a centre-zero reading show?
The side of zero shows polarity/current direction. The distance from zero shows magnitude.
Pause · explain it yourself
Why does holding a magnet still inside a stationary coil not produce continuous voltage?
Compare, then improve
The magnetic field linking the coil is not changing.
Check your physical idea, the conditions and any units. Edit your answer if a step is missing.
3
The induced effect fights the change
Direction of induction
Approaching N: the near coil face becomes N, producing repulsion that opposes the approach.Receding N: the near coil face becomes S, producing attraction that opposes separation.Generator rule: magnetic field, conductor motion and induced conventional current are mutually perpendicular.Treat direction and magnitude as two separate ledgers.
The induced effect opposes the change that causes it. This is often called Lenz's law. Do not say that it simply “opposes the magnetic field”.
Name the approaching or receding magnet pole.
Ask what force would oppose that change: repel an approach, attract a retreat.
Choose the near coil pole that creates that force.
If asked for current, convert the pole into a current direction using the solenoid rule.
Direction mnemonicCHANGE → OPPOSE → DIRECTION
State the change, select the opposing force, then infer pole/current.
Equivalent-change shortcut: reversing both magnet pole and motion can preserve the same change of field linkage and therefore the same induced deflection.
Hand-rule trap: use conventional current. For electron motion, reverse the electron-velocity direction before applying a conventional-current rule.
Quick Check · N approaches and is then pulled away at the same speed. Compare readings.
The deflections are on opposite sides of zero. Their peak magnitudes can be equal if the positions, speeds and all other conditions match.
4
Rotation makes the linkage repeat
The a.c. generator
A generator takes mechanical input and produces electrical output.
Slip rings connect a rotating a.c. coil without reversing external connections each half-turn.
Peak e.m.f. occurs at fastest linkage change, not greatest linkage.
Plane perpendicular to the field: the field linking the coil is momentarily changing at zero rate, so e.m.f. is zero.Plane parallel to the field: the field linking the coil changes fastest, so the magnitude of induced e.m.f. is maximum.One rotation of a simple two-pole generator produces one complete alternating cycle.Slip rings maintain contact; the rotating motion causes polarity reversal.
At zero e.m.f.
The plane of the coil is perpendicular to field lines. The magnetic field linking the coil is at an extreme, but momentarily is not changing.
At maximum |e.m.f.|
The plane of the coil is parallel to field lines. The field linking the coil is changing at its greatest rate.
Interactive · Generator position explorer
Connect angle, graph and speed
Change
Graph amplitude
Frequency
Polarity at same position
rotate faster
increases
increases
same
stronger field / more turns
increases
unchanged
same
reverse rotation / swap poles
unchanged if sizes match
unchanged
reverses
Position mnemonicPLANE ∥ FIELD → PEAK · PLANE ⟂ FIELD → ZERO
Read “plane of coil” carefully; confusing it with the normal reverses the answer.
Component precision: two complete slip rings maintain separate contact with the rotating coil. They do not create the alternating reversal—the changing motion through the field does.
Linkage trap: the greatest field linkage does not mean the greatest induced e.m.f. Induced e.m.f. depends on how quickly the magnetic field linking the coil changes.
Quick Check · Faster rotation changes which two graph features?
The peak magnitude increases and the peaks occur more often, so frequency increases.
5
Thumb = conventional current
Magnetic field of a straight wire
A straight current has circular magnetic field lines, related by the right-hand grip rule to conventional current.
Current out of the page (dot): field circles anticlockwise.Current into the page (cross): field circles clockwise.At the same current, the nearer point P is in the stronger field.Decode dot/cross before using the right-hand grip rule.
Field lines around a long straight wire are concentric circles centred on the wire. Their direction reverses when current reverses. Their crowding—and therefore field strength—increases with current and decreases with distance.
Interactive · Right-hand grip
Reverse the conventional current
Evidence
Conclusion
arrows circle clockwise
current is into the page
field reverses
current direction reversed
field lines closer / compass turns more
field is stronger
same distance, double current
field is stronger; direction unchanged
Page codeDOT COMES OUT · CROSS GOES IN
Imagine the point and feathers of an arrow.
Pattern plus direction: “concentric circles centred on the wire” earns pattern; “clockwise/anticlockwise by the right-hand grip rule” earns direction.
Radial-line trap: the field is not directed towards or away from the wire. It is tangential to circles around it.
Quick Check · Current emerges from the page. Field at the top of the wire?
Anticlockwise means the field arrow points left at the top of the circular path.
6
A wrapped wire behaves like a bar magnet
Magnetic field of a solenoid
A solenoid has a bar-magnet-like field, approximately uniform inside a long coil.
More current or more turns per length strengthens it; current reversal reverses poles.
Inside a long solenoid, close parallel field lines show a strong, nearly uniform field.Reverse current: every field arrow reverses and the N/S ends swap.More turns per length, larger current and a soft-iron core strengthen an electromagnet.A plotting compass reveals direction at each grid point; iron filings reveal pattern but not arrow direction.
Direction
Grip the solenoid with right-hand fingers following conventional current around its turns. The thumb points towards the N pole.
Strength
A larger current gives a stronger magnetic field. Reversing the current reverses the field direction.
Interactive · Solenoid current
Change current magnitude or direction
Change
Strength
Direction
increase current magnitude
increases
same
decrease current magnitude
decreases
same
reverse current
about unchanged for the same magnitude
reverses
Exam ruleMAGNITUDE → STRENGTH · DIRECTION → FIELD DIRECTION
Keep these two effects separate when explaining a changed current.
Field-map wording: use several compass positions; mark the direction of the needle; move the compass so its tail starts at the previous head; repeat to build a field line; repeat from different starting points.
ATP precision: keep current fixed while mapping. Switch on briefly for each observation to reduce coil heating, which otherwise changes the current.
Quick Check · Why is soft iron preferred for a relay core?
It magnetises strongly when current flows and loses most of its magnetism when current stops, so the armature can release.
Pause · explain it yourself
What happens to solenoid poles when current reverses?
Compare, then improve
North and south ends interchange because the field direction reverses.
Check your physical idea, the conditions and any units. Edit your answer if a step is missing.
7
Follow current → field → motion
Relays and loudspeakers
At rest, the armature and contacts occupy their normal positions.Coil current magnetises the core, attracts the armature and changes the separate contacts.One current direction gives a force on the coil in one direction.When alternating current reverses, the coil force reverses and the cone vibrates.
Relay chain
control current → magnetic field → soft-iron core magnetised → armature moves → contacts change
Speaker chain
alternating current → alternating magnetic force → coil and cone vibrate → pressure variations
Key distinction
A relay switches a separate circuit. A speaker continuously converts a changing signal into motion.
Name the magnetic stage and the mechanical stage for full marks.
Why a relay? A small control current can switch a separate circuit that may use a different current or voltage, while the circuits remain electrically isolated.
Steady-current trap: steady d.c. gives a steady speaker force after switch-on, not continuous vibration and therefore not a continuous tone.
Quick Check · Why should a relay core not retain strong magnetism?
Retained magnetism could keep the armature attracted after control current stops, so the contacts might not return correctly.
8
F, B and I are at right angles
The motor effect
The motor effect is force on a current-carrying conductor in a field.
Field, current and force are mutually perpendicular in the standard arrangement.
Reversing one of current or field reverses force; reversing both preserves force direction.
For a charged beam, conventional positive-charge motion sets the current direction; negative charges reverse this relationship.
Example direction map: field left to right and current upwards give force into the page.Fleming left hand links magnetic field, conventional current and force.Reverse only current: the force reverses out of the page.Use a reversal ledger before visualising the new direction.
A current-carrying conductor in a magnetic field can experience a force. Use the relative directions of conventional current, magnetic field and force. Reversing only the current or only the field reverses the force direction.
Interactive · Reversal checker
Predict the new force direction
Mark the field from N to S.
Use conventional current, not electron motion.
Hold field and current as the two known directions.
The force is perpendicular to both; use dot/cross if it enters or leaves the page.
Rule mnemonicLEFT HAND = MOTOR · RIGHT HAND = GENERATOR
Motor: current causes force. Generator: motion causes current.
Charged-particle beams: use the force–field–current direction rule. For electrons, reverse the electron-motion direction first because conventional current is opposite to electron motion. Or find the force on a positive charge and reverse it.
Poles alone are incomplete: always draw or state the magnetic field from N to S before deciding the force.
Quick Check · Both current and field reverse. New force?
The force stays in its original direction because reversing both current and field gives two direction reversals, which cancel.
9
Force pair → turn → swap → same turn
The d.c. motor
A d.c. motor instead uses supplied current and a split-ring commutator to reverse coil current each half-turn, maintaining the turning sense.
Opposite forces on the two active coil sides form a couple and produce a turning effect.Every half-turn the split-ring commutator reverses coil current, preserving the rotational direction.Component recognition: the split ring rotates with the coil; brushes remain stationary.State the allowed factor and the physical quantity it changes.
Current enters through a brush and one half of the split ring.
The two coil sides carry current in opposite directions.
Forces on those sides are opposite and form a turning couple.
After half a turn, the split ring swaps brush contact and reverses coil current.
The forces swap sides, so the turning effect continues in the same rotational direction.
Part
Moves?
Function
coil and axle
rotate
receive turning effect
split-ring halves
rotate
reverse coil connection every half-turn
brushes
stationary
sliding contact to the supply
field magnets
stationary
provide external magnetic field
Motor sequenceFORCE PAIR → TURN → SWAP → SAME TURN
The current reverses in the coil so the rotation does not reverse.
Do not say only “the commutator keeps it spinning”. State what it reverses, when it reverses it, and why the turning direction remains unchanged.
Ring trap: a d.c. motor uses a split ring. A simple a.c. generator uses two complete slip rings.
Quick Check · Three ways to increase motor turning effect?
Increase the number of turns, the current, or the magnetic-field strength.
10
A changing field links two coils
How a transformer works
Primary and secondary coils are linked by a soft-iron core.
Alternating primary current creates changing magnetic linkage and induces secondary e.m.f. Steady d.c. gives no sustained transformer output after switching transients.
Step-down transformer: the secondary has fewer turns and a smaller voltage.Step-up transformer: the secondary has more turns and a larger voltage.The soft-iron core carries a changing magnetic field that links both coils.After switching, steady d.c. makes a steady core field, so there is no continuous secondary e.m.f.
An alternating current flows in the primary.
It creates a changing magnetic field in the soft-iron core.
The changing field links the secondary coil.
The changing linkage induces an alternating e.m.f. across the secondary.
Construction
Two separate insulated copper coils are wound on a shared soft-iron core. There is no direct electrical connection between the windings.
Why soft iron?
It magnetises and demagnetises readily, guiding the changing field through both windings.
Causal mnemonicA.C. → CHANGE → LINK → INDUCE
Alternating current changes the core field; the linked change induces secondary e.m.f.
Four-link answer: mention alternating primary current, changing core field, linkage to secondary, and induced alternating secondary e.m.f.
D.C. trap: d.c. does create a magnetic field. The problem is that after the switching moment the field is steady, so it cannot maintain induction.
Quick Check · Are primary and secondary joined by a conducting wire?
No. They are electrically separate. Energy transfers through the changing magnetic field in the shared core.
11
Match every primary with p and secondary with s
Transformer ratios
Vs/Vp = Ns/Np relates voltage and turns.
The voltage ratio equals the turns ratio; equal input/output power applies only to an ideal transformer.Worked visual: fewer secondary turns means a step-down output.Keep corresponding quantities on the same side of the ratio.Find power first when the current calculation feels crowded.
$\dfrac{V_p}{V_s}=\dfrac{N_p}{N_s}$ and for an ideal transformer $I_pV_p=I_sV_s$
Interactive · Transformer solver
Turns, voltage and ideal current
Mark which coil is primary: it receives the input.
Write one consistent ratio before substituting.
Use the turns ratio to calculate voltage.
Only if ideal / 100% efficient, equate input and output power.
Sense-check: step-up voltage must pair with step-down current.
Transformer
Turns
Voltage
Ideal load current
step-up
$N_s>N_p$
$V_s>V_p$
$I_s<I_p$
step-down
$N_s<N_p$
$V_s<V_p$
$I_s>I_p$
Ratio mnemonicVOLTS FOLLOW TURNS · IDEAL CURRENT GOES OPPOSITE
More secondary turns means more secondary voltage, but less secondary current at equal power.
Ratio flip trap: $V_p/V_s$ must pair with $N_p/N_s$. Never mix a primary numerator with a secondary-turn numerator.
Quick Check · A transformer raises voltage fourfold. Ideal current change?
The secondary current is one quarter of the primary current because input and output powers are equal.
12
High V makes current small at fixed power
High-voltage transmission
Ideally VpIp = VsIs, so stepping voltage up steps current down for the same power.
Cable heating loss is I²R.
High-voltage transmission helps because it reduces current at a given transmitted power, not because cable resistance disappears.
A step-up transformer cannot create power; real transformers also have losses.
Generation → step up → long high-voltage cables → step down near users.Reducing current by a factor of five reduces cable heating loss by a factor of twenty-five.Use fixed transmitted power to find current, then square current for cable loss.At fixed power and resistance, cable loss varies inversely with voltage squared.
For the transmitted power, calculate cable current using $I=P/V$.
Calculate heating loss using $P_{loss}=I^2R$.
If voltage changes by a factor, current changes by the inverse factor.
Square the current factor to compare losses.
Interactive · Grid-loss comparator
Raise voltage, watch $I^2R$ collapse
Worked comparison: Transmit $2.0\,MW$ through $4.0\,Ω$. At $20\,kV$, $I=100\,A$ and loss $=40\,kW$. At $200\,kV$, $I=10\,A$ and loss $=0.40\,kW$. Ten times the voltage gives one hundredth of the loss.
Grid mnemonicHIGH V → LOW I → MUCH LOWER I²R
The word “much” matters because the current is squared.
Complete advantage: for the same transmitted power, higher voltage means lower current; lower current gives less $I^2R$ heating, so less energy is wasted in the cables.
Safety claim trap: high transmission voltage is not safer to touch. Its advantage is efficiency; voltage is stepped down near consumers.
Quick Check · Cable current becomes one quarter. Loss factor?
$P_{loss}$ becomes $(1/4)^2=1/16$ of its original value if cable resistance is unchanged.
Pause · explain it yourself
Why step up voltage for long-distance transmission?
Compare, then improve
For the same power it lowers current, reducing I²R cable losses.
Check your physical idea, the conditions and any units. Edit your answer if a step is missing.
13
Alternative to Practical
ATP Lab Lens · define the measurable quantity, control geometry, repeat and link every improvement
Induction ATP: measure speed near the coil, capture peak magnitude and repeat at each setting.Field mapping ATP: mark compass direction at each point while keeping current fixed.Motor-effect ATP: a balance can measure the equal-and-opposite reaction on the magnet system.Transformer ATP: use prewound insulated coils and an isolated current-limited low-voltage a.c. source.
Induction
Independent: magnet speed at the coil. Dependent: peak magnitude of induced e.m.f. Controls: magnet, coil, path, orientation and sensor settings.
Force
Independent: current. Dependent: balance change or force. Controls: wire length in field, angle, position, field strength and temperature.
Transformer
Independent: secondary turns. Dependent: secondary a.c. voltage. Controls: primary turns/voltage, frequency, core, coil position and meter range.
Investigation
Graph
Expected pattern
Best linked evaluation
peak e.m.f. vs speed
mean peak |e.m.f.| against speed
increasing, approximately proportional under fixed geometry
measure speed at coil, not launch speed
force vs current
mean force against current
straight line near origin
brief current and cooling reduce heating drift
$V_s$ vs $N_s$
mean secondary voltage against turns
straight line near origin
monitor $V_p$ to detect source drift
Draw an apparatus that could produce both variables.
Name independent, dependent and at least five controls.
Use five or more settings over a sensible range.
Repeat each setting, identify anomalies and calculate a mean.
Give table headings with units and name both graph axes.
Link each limitation to its physical effect and a specific improvement.
ATP chainAPPARATUS → VARIABLES → REPEATS → MEAN → GRAPH → LINKED EVALUATION
An improvement earns strength when it directly fixes the stated limitation.
Direction evidence: a centre-zero meter records sign; a plotting compass records direction; iron filings only show field pattern.
Safe practical: use only teacher-approved isolated, current-limited low-voltage equipment and insulated prewound coils. Never connect student-built apparatus to mains. Switch off before repositioning leads or coils; stop if conductors become warm.
Quick Check · Why repeat a reference transformer reading?
Returning to the same reference coil reveals source or temperature drift, helping identify whether changes in $V_s$ were really caused by turns.
1
See the trigger before the formula
One picture decoder separates induction, motor effect and transformers
Changing magnetic linkage gives induction; current in a magnetic field gives force; alternating current linking two coils gives transformer action.Induction question: ask whether the magnetic field linking the coil is changing.Motor-effect question: label field and conventional current, then find the perpendicular force.Transformer question: build the complete causal chain from alternating current to induced secondary e.m.f.
Examiner habit: do not start with a hand rule or equation. First identify the physical trigger. “A magnet is present” is not enough for induction; “a wire carries current” is not enough for a force unless the current has a component across the field.
Induction
A conductor cuts field lines or the magnetic field linking a circuit changes.
Motor effect
A current-carrying conductor lies in an external magnetic field.
Transformer
A changing current in one coil makes a changing linked field in another.
Master mnemonicCHANGE · CURRENT · COILS
Change → induction. Current across a field → force. Two linked coils with a.c. → transformer.
Three traps: a stationary magnet does not continuously induce; a wire parallel to the field has zero magnetic force; a transformer needs a changing primary current.
Quick Check · Magnet and coil move together with fixed separation. Induced e.m.f.?
No continuing e.m.f. Their motion relative to the room is irrelevant: the magnetic field linking the coil is unchanged.
14
One-page examiner logic
Master Electromagnetic Effects by tracking change, directions, components and ratios
Stage 1: identify induction, motor effect or transformer action.Stage 2: label the two given perpendicular directions before finding the third.Stage 3: connect generator coil position with zero, peak, trough and reversal.Stage 4: choose the correct ratio, then sense-check the direction of change.Stage 5: finish the transmission explanation with lower current and much lower heating loss.
1 · Track change
Induction needs changing linkage. The induced effect opposes the change.
2 · Track direction
Decode N→S, conventional current, motion and dot/cross before using a rule.
3 · Track components
Slip rings maintain generator contact; split ring reverses motor-coil current.
4 · Track ratios
Voltage follows turns; ideal current changes oppositely; cable loss follows $I^2$.
INDUCTION: changing linkage | MOTOR: current across field → force | TRANSFORMER: $V_p/V_s=N_p/N_s$ | GRID: $P_{loss}=I^2R$
Final chainCHANGE · OPPOSE · LABEL · TURN · LINK · RATIO · SQUARE
That sequence covers the entire topic from magnet-coil observations to grid efficiency.
Final check · Transformer raises voltage ×4; grid voltage then rises ×5. Ideal current and cable-loss factors?
Ideal transformer current becomes one quarter. At fixed transmitted power, the fivefold grid-voltage rise makes cable current one fifth and cable loss one twenty-fifth.
Interactive mastery: 0 / 9 explored
Explore all nine checkpoints, then move to the independent Practice and Exam Arena banks.