WONDER — The Mystery
Circles Around a Straight Current
A straight wire carries current, yet the magnetic field does not run along it. A compass placed in the plane perpendicular to the wire turns tangentially to a circle around the axis. What determines its direction and the field magnitude?
Model: Outside an ideal long straight wire in vacuum, B = μ₀|I|/(2πr). The direction is tangent to circles centered on the wire and follows the right-hand grip rule. Distances are perpendicular distances from the axis. A compass aligns with the total field in its allowed plane of rotation.
PREDICT — Commit to Your Answer
DOK 2 — PredictA long wire carries current out of the page. At a probe directly to its right, what direction is the wire’s magnetic field?
Commit to both a prediction and a reason before revealing the explanation.
Step 1: Pick your answer.
STOP! Before revealing — why did you pick that?
Correct prediction and reasoning saved.
Current out of the page gives counterclockwise field circulation; the tangent at the right-hand point is upward.
▶ PLAY — A Compass in the Wire’s Cross-Section
DOK 2 — InvestigatePredict, measure and compare
Compare two currents at one probe distance, then change distance at one current. Run the settling compass and compare signed tangential fields. Include a reversed-current check.
The wire is perpendicular to the screen, with signed conventional current I positive out of the page. Its radius is much smaller than the probe distance, and nearby ends, return wires and external fields are neglected. At the right-hand probe, By = 2×10⁻⁷ I/r T. A freely turning model compass starts along +x and obeys an overdamped torque response dα/dt = 100000|B| sin(αfield − α), with time in seconds and B in teslas. The damping constant is a chosen illustrative compass parameter. Field lines are stationary directions, not moving material. Only the needle moves. Six model seconds play over six real seconds. Drawn distances are schematic.
Status: Ready
Playback: 6 real seconds per run; read elapsed physical model time. Pause or Step for measurements.
Measurements
Load givens — then predict and run
Loading a setup earns no trial credit.
♢ DISCOVER — Shape, Direction, Magnitude and Scope
DOK 1 — RecallFlip all 4 rule cards. Keep the quantities and model conditions clear.
Rule 1
A specified viewpoint
Click to flip
A specified viewpoint
Viewed with current coming toward you, the field circles counterclockwise. With current away, it circles clockwise. “Current up means counterclockwise” is incomplete without a viewing direction.
Rule 2
Magnitude outside a long wire
Click to flip
Magnitude outside a long wire
B = μ₀|I|/(2πr), with μ₀ ≈ 4π×10⁻⁷ T m/A for school calculations. Use amperes and meters. The model assumes an effectively long wire and free space; it is not valid at the central axis.
Rule 3
Scaling with controls
Click to flip
Scaling with controls
At fixed r, magnitude is proportional to |I|. At fixed I it is inversely proportional to r. Doubling both gives the same magnitude. Current reversal reverses the field direction.
Rule 4
A real compass
Click to flip
A real compass
A compass needle responds to total local magnetic field and its mounting constrains motion. A horizontal compass cannot simply point through its dial into a page. In this model the screen is the transverse plane and the needle can turn within that plane.
All rules explored.
MISCONCEPTION ATTACK — Destroy the Myths
DOK 2 — AnalyzeChoose TRUE or FALSE for each claim. The explanation appears after an attempt; only a correct answer completes the claim.
Myth 1: “A wire’s field is radial or parallel to its current.”
Correct — the claim is false.
False. For an ideal long wire it is tangential to concentric circles in planes perpendicular to the current.
Myth 2: “The outside-wire formula predicts the field at r = 0.”
Correct — the claim is false.
False. It becomes singular for an ideal line current. A finite, symmetric, uniformly conducting cylindrical wire instead has B = 0 at its axis.
Both myths corrected. Continue to the instructor questions.
✦ THE SECOND “AHA!” — Grip Rule and Scaling Checks
DOK 2 — ApplyState the viewpoint and apply the external long-wire model.
Instructor Q1 — Into the Screen
Current is into the page. At a point to the right of the wire, the field points:
Instructor Q2 — Equal Changes
Current magnitude and probe distance both double. Field magnitude:
Instructor Q3 — Field Magnitude
Find B at 0.050 m from a long wire carrying 4.0 A.
Instructor Q4 — Distance Conversion
A fixed-current field is 24 μT at 3.0 cm. Find it at 6.0 cm.
4/4 — Instructor Questions Completed
A field direction is a tangent, not a moving path of magnetic material. Keep the current, radial displacement and field mutually perpendicular.
✎ PRACTICE — Independent Wire-Field Calculations
DOK 1–3 — PracticeChallenge 1: Compute the External Field
A long straight wire carries 5.0 A in free space. Find the magnetic-field magnitude at perpendicular distance 0.10 m from its axis. Give any equivalent valid decimal or scientific-notation answer.
Step-by-Step Solution
B = (2×10⁻⁷)(5.0)/0.10 = 1.0×10⁻⁵ T = 0.000010 T = 10 μT.
Challenge 2: Two Controls Change
A 3.0 A wire produces a 15 μT field at a probe. Keeping the long-wire geometry, the current becomes 6.0 A and the probe distance triples. Find the new field magnitude and the original probe distance.
Step-by-Step Solution
Bnew = 15(6/3)/3 = 10 μT. rinitial = (2×10⁻⁷)(3)/(15×10⁻⁶) = 0.040 m.
Challenge 3: Audit the Axis and Compass Claims
A long solid cylindrical wire of radius 2.0 mm carries 8.0 A uniformly through its cross-section. A report applies the outside formula at the axis and predicts infinite field; it also says a horizontal compass at a point where the wire field is vertical must point into its own dial. Find B at the axis and at r = 10 mm. Correct both claims, distinguish the finite conductor from a line-current model, and propose a controlled test of inverse-distance scaling outside the wire.
Explanation checks are indicative. Compare your reasoning with the worked solution or your teacher.
Step-by-Step Solution
Symmetry gives Baxis = 0 for the specified uniform finite conductor. At 0.010 m, B = (2×10⁻⁷)(8)/0.010 = 1.6×10⁻⁴ T. The ideal line-current singularity is not the field inside a finite conductor. A horizontal needle cannot rotate vertically into its dial; use a correctly oriented probe or compass and account for background fields. Keep current fixed, take readings at multiple outside distances from the axis, and test whether Br is approximately constant.
☷ CHALLENGE — Direction in a Specified Page
DOK 2 — ApplyDirection in a Specified Page
Select each statement and place it in its matching category. Judge the physical conditions.
0 / 6 correct
Physics Insight
A field direction is a tangent, not a moving path of magnetic material. Keep the current, radial displacement and field mutually perpendicular.
TEACH — The Feynman Technique
DOK 3 — TeachYour Final Mission: Explain the long-wire field pattern, a grip-rule example with a stated viewpoint, inverse-distance scaling, and why a compass mounting and the finite wire radius matter.
Use simple words and at least three short sentences. This checks effort; compare your physics with the Vault or your teacher.
Type Your Explanation (≥ 3 sentences)
Draw a labelled explanation with at least three purposeful strokes. This checks effort; compare your physics with the Vault or your teacher.
Cyan pen selected.
Final reward below
Hidden exam secrets inside — Crest's private notebook.
Crest’s Secret Notebook
Mission 11.6 — Magnetic Field of a Straight Wire
Reach the Peak of Understanding
1. A specified viewpoint
Viewed with current coming toward you, the field circles counterclockwise. With current away, it circles clockwise. “Current up means counterclockwise” is incomplete without a viewing direction.
2. Magnitude outside a long wire
B = μ₀|I|/(2πr), with μ₀ ≈ 4π×10⁻⁷ T m/A for school calculations. Use amperes and meters. The model assumes an effectively long wire and free space; it is not valid at the central axis.
3. Scaling with controls
At fixed r, magnitude is proportional to |I|. At fixed I it is inversely proportional to r. Doubling both gives the same magnitude. Current reversal reverses the field direction.
4. A real compass
A compass needle responds to total local magnetic field and its mounting constrains motion. A horizontal compass cannot simply point through its dial into a page. In this model the screen is the transverse plane and the needle can turn within that plane.
5. Inside a finite uniform wire
For radius a and uniform current density, B(r) = μ₀|I|r/(2πa²) for 0 ≤ r ≤ a; it grows from zero at the axis and joins the outside expression at r = a. This statement assumes a long symmetric cylindrical conductor.
6. Analogy boundaries
A tornado can remind you of circular directions, but magnetic field lines are not streams of air and do not travel around a DC wire. Wind-speed laws are not magnetic-field equations.
7. Magnitude and background
At equal distances around an ideal isolated long wire, magnitudes match. A nearby return wire, other sources or finite ends can invalidate that simple symmetry; add fields as vectors.
Worked independent practice
C1: 1×10⁻⁵ T. C2: 1×10⁻⁵ T and 0.040 m. C3: zero axis field and 1.6×10⁻⁴ T outside; distinguish finite-wire physics and compass constraints, then hold current fixed in an outside-distance investigation.
Live investigation and access
The wire is perpendicular to the screen, with signed conventional current I positive out of the page. Its radius is much smaller than the probe distance, and nearby ends, return wires and external fields are neglected. At the right-hand probe, By = 2×10⁻⁷ I/r T. A freely turning model compass starts along +x and obeys an overdamped torque response dα/dt = 100000|B| sin(αfield − α), with time in seconds and B in teslas. The damping constant is a chosen illustrative compass parameter. Field lines are stationary directions, not moving material. Only the needle moves. Six model seconds play over six real seconds. Drawn distances are schematic.
Run, Pause, Step and Reset work offline. Complete three matched measurements. Loading a preset is not completing a trial. Saved progress resumes paused. Reduced-motion Run gives a final snapshot; Step allows deliberate inspection. Hints and solutions require a genuine unsuccessful numerical attempt and never complete a task. Explanation rubrics are indicative; compare your physics with the solution or a teacher. Teaching submission checks effort rather than certifying scientific accuracy.
Course scope
A Level 9702 20.4 requires straight-wire field patterns. The long-wire magnitude formula and finite-wire interior analysis are marked quantitative extensions for that syllabus. AP Physics 2 12.3 includes the long straight-wire magnitude, directions and superposition. The torque-settling equation is an illustrative extension.
Sources: Cambridge International 9702 syllabus ; College Board AP Physics 2 CED. Detailed extension models are labelled in the mission.
✓ Crest’s Checklist
- I specify the viewpoint.
- I use conventional current.
- I measure r from the axis.
- I convert distances to meters.
- I use the outside formula only outside the wire.
— Crest ☆ “Reach the Peak of Understanding”
Mission 11.6 Complete! · All 10 levels cleared · PHYSICS CREST
★ Magnetic Field of a Straight Wire Investigator
A field direction is a tangent, not a moving path of magnetic material. Keep the current, radial displacement and field mutually perpendicular.