Skip to lesson
PC

PHYSICS CREST

Global Physics Academy

Mission 11.3 · Magnetic Flux and Induction Reach the Peak of Understanding
Journey Tracker
Progress
0/10
1

WONDER — The Mystery

Presence or Change?

A fixed magnet near a stationary coil can produce a nonzero magnetic flux while the induced e.m.f. is zero. Approach and withdrawal can produce opposite responses. What changes when the magnet moves relative to the coil?

Magnet and loopFixed relative geometryThen approach/withdrawNS
Given conditions only; arrows and distances are schematic.

Model: Magnetic flux is the surface integral of B through a chosen oriented area, not a literal count of drawn lines. For a uniform field and flat loop, Φ = BA cosθ with θ measured from the area normal. Induction depends on change of flux linkage; current additionally needs a conducting path.

2

PREDICT — Commit to Your Answer

DOK 2 — Predict

A magnet and small coil translate together, keeping relative geometry fixed. There are no other changing external fields and the ideal model gives constant flux linkage. What induced e.m.f. results?

Magnet and loopFixed relative geometryThen approach/withdrawNS
Given conditions only; arrows and distances are schematic.

Commit to both a prediction and a reason before revealing the explanation.

Step 1: Pick your answer.

STOP! Before revealing — why did you pick that?

3

▶ PLAY — A Magnet Passes Through a Closed Coil

DOK 2 — Investigate

Predict, measure and compare

Measure two speeds with the same polarity, then reverse only polarity at one of those speeds. Watch the magnet move and the signed galvanometer response reverse with the rate of flux change.

Extension model: a point dipole of signed moment ±0.50 A m² moves along the axis of a thin circular 50-turn coil of radius a = 0.025 m. z = 0.120 − vt metres. Exact point-dipole flux through each circular loop is Φ = (μ₀ m a²)/(2(a²+z²)³ᐟ²), with μ₀ = 4π×10⁻⁷ SI. E.m.f. = −50 dΦ/dt; current = e.m.f./10 Ω in a closed resistive circuit, neglecting self-inductance and back reaction. Positive normal points +z; positive circulation is counterclockwise viewed from +z. Each run lasts 6 model seconds over 6 real seconds. Bars, turns and charge-marker speed are schematic. Pause freezes the model state; it is not a physical stop of the prescribed trajectory. Set v = 0 to investigate a stationary magnet.

Use the labelled readouts.

Status: Ready

Playback: 6 real seconds per run; read elapsed physical model time. Pause or Step for measurements.

Measurements

Model time:
Axial coordinate:
Signed flux per turn:
Flux linkage:
Flux change rate per turn:
Signed induced e.m.f.:
Signed circuit current:

Load givens — then predict and run

Loading a setup earns no trial credit.

4

♢ DISCOVER — Flux Is an Oriented Surface Quantity

DOK 1 — Recall

Flip all 4 rule cards. Keep the quantities and model conditions clear.

Rule 1

Field and flux differ

Click to flip

Field and flux differ

B is a vector field measured in teslas. Flux Φ is an oriented surface quantity measured in webers. For a uniform field over a flat area Φ = BA cosθ; in a nonuniform field contributions must be summed over the surface.

Rule 2

Choose the normal

Click to flip

Choose the normal

θ is between B and the area normal, not between B and the plane. At 0° the positive flux is maximal; at 90° it is zero. Reversing the chosen normal reverses the flux sign.

Rule 3

Linkage and induction

Click to flip

Linkage and induction

For N identical turns with equal flux, linkage is NΦ. E.m.f. is −d(NΦ)/dt. Nonzero flux need not mean nonzero e.m.f.; changing B, A or orientation matters only when it changes linkage.

∫

Rule 4

E.m.f. is not current

Click to flip

E.m.f. is not current

An open coil may have induced e.m.f. without sustained current. In a closed resistive idealization current equals e.m.f./R. Real circuits can also have inductance and other effects.

Flip all 4 cards to reveal the rules. 0/4 flipped
5

MISCONCEPTION ATTACK — Destroy the Myths

DOK 2 — Analyze

Choose TRUE or FALSE for each claim. The explanation appears after an attempt; only a correct answer completes the claim.

Myth 1: “A nonzero constant flux linkage must induce a continuous current.”

Myth 2: “Flux is the number of lines an artist draws through the coil.”

6

✦ THE SECOND “AHA!” — Normal Angles and Linkage

DOK 2 — Apply

Use the angle to the area normal and keep per-turn quantities separate.

Progress
0/4
Magnet and loopFixed relative geometryThen approach/withdrawNS
Given conditions only; arrows and distances are schematic.

1

Instructor Q1 — Maximum Flux

A uniform B passes through a fixed flat loop. Positive flux is greatest when the normal is:

2

Instructor Q2 — Open Loop

An open coil’s flux linkage changes. Which statement is possible?

3

Instructor Q3 — Uniform Flux

A flat area 0.030 m² has a uniform 0.40 T field normal to it. Find flux.

Uniform FluxB: 0.40 TArea: 0.030 m²Normal alignedNS
Given conditions only; arrows and distances are schematic.
Wb
4

Instructor Q4 — Equal Turns

An 80-turn coil has flux 0.0020 Wb per turn. Find flux linkage.

Equal Turns80 equal turnsPer turn: 0.0020 WbNS
Given conditions only; arrows and distances are schematic.
Wb
7

✎ PRACTICE — Independent Flux and Evidence Problems

DOK 1–3 — Practice
DOK 1 — Routine

Challenge 1: Oriented Flux

A uniform 0.35 T magnetic field passes through a flat loop of area 0.012 m². The field makes 60° with the positive area normal. Find the signed magnetic flux.

Oriented FluxB: 0.35 TArea: 0.012 m²B to normal: 60°NS
Given conditions only; arrows and distances are schematic.
Wb
DOK 2 — Application

Challenge 2: Normal or Plane?

A 120-turn coil of area 0.0080 m² lies in a uniform 0.25 T field. The field is 30° to the plane of the coil and points through its chosen positive side. Find flux per turn and total flux linkage.

Normal or Plane?120 equal turnsB: 0.25 TArea: 0.0080 m²B to plane: 30°NS
Given conditions only; arrows and distances are schematic.
Wb
Wb
DOK 3 — Audit & Justify

Challenge 3: Audit a Fixed Coil

A stationary 60-turn coil of area 0.010 m² is held in a constant uniform 0.20 T field making 60° with its positive normal. A report says: “Flux per turn is 0.0020 Wb, flux linkage has units tesla, and the nonzero linkage guarantees a steady induced e.m.f.” Find the correct flux per turn and the induced e.m.f. Explain all three errors and state what extra information would be needed to calculate current if the geometry began changing.

Audit a Fixed Coil60 turns; fixedB: constant 0.20 TArea: 0.010 m²B to normal: 60°NS
Given conditions only; arrows and distances are schematic.
Wb
V

Explanation checks are indicative. Compare your reasoning with the worked solution or your teacher.

8

☷ CHALLENGE — Induced E.M.F., Current or Neither?

DOK 2 — Apply

Induced E.M.F., Current or Neither?

Select each statement and place it in its matching category. Judge the physical conditions.

0 / 6 correct

9

TEACH — The Feynman Technique

DOK 3 — Teach

Your Final Mission: Explain why a moving magnet can induce an e.m.f., why common motion can leave linkage unchanged, why an open coil need not carry current, and how a plane angle differs from a normal angle.

Use simple words and at least three short sentences. This checks effort; compare your physics with the Vault or your teacher.

Type Your Explanation (≥ 3 sentences)

Final reward below

Hidden exam secrets inside — Crest's private notebook.