WONDER — The Mystery
Small Charges, Measurable Forces
Microcoulomb and nanocoulomb prefixes make small charges convenient to write, but Coulomb’s law with the SI constant requires coulombs and metres. The law gives a nonnegative force magnitude when absolute charge values are used. Directions then follow from signs and geometry; a negative Cartesian force means left in a chosen axis, not automatically attraction.
Model: For point charges in vacuum, use F = k|qAqB|/r² with rounded k = 9.00 × 10⁹ N m²/C² and r > 0. Air is approximately vacuum for this lesson. For A left of B with right positive, FA = −kqAqB/r² and FB = −FA. Convert μC = 10⁻⁶ C, nC = 10⁻⁹ C and cm = 10⁻² m before substitution.
PREDICT — Commit to Your Answer
DOK 2 — PredictA at the left has +2.0 μC and B at the right −3.0 μC, separated by 0.60 m in vacuum. Which result is correct using k = 9.00 × 10⁹ N m²/C²?
Commit to both a prediction and a reason before revealing the explanation.
Step 1: Pick your answer.
STOP! Before revealing — why did you pick that?
Correct prediction and reasoning saved.
F = 9.00 × 10⁹(2.0 × 10⁻⁶)(3.0 × 10⁻⁶)/(0.60)² = 0.150 N. Opposite charges attract: right on A, left on B.
▶ PLAY — Live Coulomb Motion and Calculation
DOK 2 — InvestigatePredict, measure and compare
Complete two runs changing only A’s charge, then a third changing only initial separation. Watch the particles move and the current separation, charge product and force values change. Pause to compare the displayed calculation with the instantaneous positions.
Two point particles start at rest with the selected centre-to-centre separation. A has mass 0.50 kg and B 1.00 kg. Their charges are specified in μC; the model converts them to C and initial cm to m. A velocity-Verlet calculation with small time steps recomputes Coulomb force for 0.50 model seconds. An ideal catch stops both if separation reaches 0.10 m; later electric forces are balanced by the catch, so they no longer imply net acceleration. Other external forces are otherwise neglected on the horizontal line. Right is positive. The drawing rescales to keep both particles visible; numerical separation is authoritative. A zero-charge point particle does not model neutral-body polarization.
Status: Ready
Playback: 8 real seconds per run; read elapsed physical model time. Pause or Step for measurements.
Measurements
Load givens — then predict and run
Loading a setup earns no trial credit.
♢ DISCOVER — Units, Magnitude and Geometry
DOK 1 — RecallFlip all 4 rule cards. Keep the quantities and model conditions clear.
Rule 1
SI conversion first
Click to flip
SI conversion first
Use C and m with k in N m²/C². Each μC conversion supplies 10⁻⁶, each nC conversion 10⁻⁹. Convert the distance before squaring it; 12 cm becomes 0.12 m, whose square is 0.0144 m².
Rule 2
Nonnegative magnitude
Click to flip
Nonnegative magnitude
F = k|qAqB|/r² is the magnitude. It is positive for two nonzero charges, zero if one point charge is zero. Do not attach a negative sign to a magnitude.
Rule 3
Direction needs a geometry
Click to flip
Direction needs a geometry
Like signs repel; opposite signs attract. For A left of B with right positive, FA = −kqAqB/r² and FB = −FA. Positive or negative axis components do not universally mean repulsion or attraction.
Rule 4
Rearrange and check the model
Click to flip
Rearrange and check the model
For F > 0, r = √(k|qAqB|/F) and |qB| = Fr²/(k|qA|). Infer charge sign from the stated direction or interaction, not from a magnitude alone. k is fixed for a fixed medium; material polarization requires an appropriate model.
All rules explored.
MISCONCEPTION ATTACK — Destroy the Myths
DOK 2 — AnalyzeChoose TRUE or FALSE for each claim. The explanation appears after an attempt; only a correct answer completes the claim.
Myth 1: “A negative result is a valid force magnitude because the charges attract.”
Correct — the claim is false.
False. Magnitude is nonnegative; attraction is a direction relation between the two bodies.
Myth 2: “Changing a charge changes the vacuum Coulomb constant.”
Correct — the claim is false.
False. k is independent of charge magnitude. The medium’s permittivity matters when a different material model is specified.
Both myths corrected. Continue to the instructor questions.
✦ THE SECOND “AHA!” — Convert, Calculate and Rearrange
DOK 2 — ApplyUse k = 9.00 × 10⁹ N m²/C² throughout; report the requested magnitude or signed component precisely.
Instructor Q1 — Attraction Axis
A positive charge lies left of a negative B. With right positive, what is the direction of the electric force on A?
Instructor Q2 — Prefix Error
Which conversion is correct?
Instructor Q3 — A Force Magnitude
Charges +2.0 μC and +1.0 μC are 0.30 m apart. Find the electric force magnitude.
Instructor Q4 — Find Separation
Two point charges of magnitude 2.0 μC each exert a force magnitude 0.40 N. Find their separation.
4/4 — Instructor Questions Completed
Convert each input before calculating, then report magnitude and direction as distinct information.
✎ PRACTICE — Independent SI Calculations
DOK 1–3 — PracticeChallenge 1: Magnitude from Mixed Units
Point charges +2.40 μC and −1.50 μC are separated by 30.0 cm in vacuum. Use k = 9.00 × 10⁹ N m²/C². Determine the force magnitude.
Step-by-Step Solution
qA = 2.40 × 10⁻⁶ C, |qB| = 1.50 × 10⁻⁶ C and r = 0.300 m. F = 9.00 × 10⁹(3.60 × 10⁻¹²)/0.0900 = 0.360 N. The pair attracts.
Challenge 2: Unknown Charge and New Separation
A point charge of +4.00 μC attracts a negative point charge B with force magnitude 1.25 N at 24.0 cm separation in vacuum. Use k = 9.00 × 10⁹ N m²/C². Determine B’s signed charge, then the separation at which these same charges exert magnitude 0.3125 N.
Step-by-Step Solution
|qB| = Fr²/(k|qA|) = 1.25(0.240)²/[9.00 × 10⁹(4.00 × 10⁻⁶)] = 2.00 μC. Since B is negative, qB = −2.00 × 10⁻⁶ C. The new r = √[9.00 × 10⁹(4.00 × 10⁻⁶)(2.00 × 10⁻⁶)/0.3125] = 0.480 m.
Challenge 3: Audit a Calculation Report
A lies left of B. Their charges are +6.00 nC and −3.00 nC, and their separation is 12.0 cm in vacuum. Use k = 9.00 × 10⁹ N m²/C²; right is positive. A report substitutes charge numbers 6 and −3 and distance number 12 without SI conversion, reports a negative force magnitude, and says attraction means A’s force points left. Determine the correct magnitude and both signed mutual forces. Explain all three errors.
Step-by-Step Solution
Use 6.00 × 10⁻⁹ C, −3.00 × 10⁻⁹ C and 0.120 m. F = 9.00 × 10⁹(18.0 × 10⁻¹⁸)/0.0144 = 1.125 × 10⁻⁵ N.
Magnitude cannot be negative. Opposite charges attract, so A feels +1.125 × 10⁻⁵ N to the right and B −1.125 × 10⁻⁵ N to the left. Unconverted charge numbers and centimetres are incompatible with the SI k; convert first, then square the SI distance.
☷ CHALLENGE — Classify the SI Quantity
DOK 2 — ApplyClassify the SI Quantity
Place each correctly converted quantity in its physical category.
0 / 6 correct
Physics Insight
A conversion preserves the physical quantity while changing its written number and unit prefix.
TEACH — The Feynman Technique
DOK 3 — TeachYour Final Mission: Explain how to calculate a Coulomb-force magnitude from prefixed charges and centimetres. Include the point-charge assumptions, SI conversions, squared separation, the rounded constant, and how geometry determines the two signed force components.
Use simple words and at least three short sentences. This checks effort; compare your physics with the Vault or your teacher.
Type Your Explanation (≥ 3 sentences)
Draw a labelled explanation with at least three purposeful strokes. This checks effort; compare your physics with the Vault or your teacher.
Cyan pen selected.
Final reward below
Hidden exam secrets inside — Crest's private notebook.
Crest’s Secret Notebook
Mission 9.8 — Coulomb’s Law Calculations
Convert to SI, calculate a magnitude, then assign each force direction.
1. Coulomb’s law
F = k|qAqB|/r², r > 0
Use rounded k = 9.00 × 10⁹ N m²/C² in vacuum or approximately air. The magnitude is nonnegative and is positive for nonzero point charges. It describes ideal point charges and suitable small-object approximations, not arbitrary extended polarizable bodies.
2. Units and notation
μC = 10⁻⁶ C, nC = 10⁻⁹ C, pC = 10⁻¹² C. cm = 10⁻² m and mm = 10⁻³ m. Convert both charges and the distance first, then square the distance. For example, (12 cm)² = (0.12 m)² = 0.0144 m². The coulomb remains the SI unit; micro and nano are convenient prefixes, not replacements for SI in a formula.
Two 1 C ideal point charges at 1 m give 9.00 × 10⁹ N under this model, but 1 C is not universally impossible or unused. A force from “1 μC” cannot be specified without the other charge and separation. Reducing both charge magnitudes by 10⁻⁶ reduces their product by 10⁻¹².
3. Magnitude and axis direction
Like signs repel; opposite signs attract. For A left of B, define right positive. Then FA = −kqAqB/r² and FB = −FA. A signed component depends on the axis and the body; a negative scalar product merely identifies the opposite-sign interaction. “Positive = repel” and “negative = attract” are not universal Cartesian conventions.
4. Rearrangement
r = √(k|qAqB|/F); |qB| = Fr²/(k|qA|)
These rearrangements require F > 0 and the stated nonzero known charges. A force magnitude alone cannot identify the unknown charge’s sign. In an appropriate homogeneous material model, permittivity affects the interaction coefficient; do not automatically apply a dielectric-only formula to a conducting liquid that can exchange or screen charge. Changing q does not change the vacuum k.
5. Live calculation and motion
A has mass 0.50 kg and B 1.00 kg. Both start at rest on a horizontal line at the selected separation. μC and cm are converted before a small-step velocity-Verlet calculation advances 0.50 model seconds. The current force changes as the point-to-point separation changes. An ideal catch stops motion at 0.10 m; electric force continues but is then balanced by support, so its F/m contribution is not the net acceleration.
The drawing rescales to remain visible and marker positions are schematic. The numerical separation is authoritative. A zero-charge point model does not polarize. Half a model second plays over eight real seconds. Compare A charge with other controls fixed, then initial separation with charges fixed.
6. Worked practice
+2.40 μC and −1.50 μC at 0.300 m give magnitude 0.360 N. The unknown negative charge is −2.00 μC; reducing the force from 1.25 N to 0.3125 N doubles separation from 0.240 m to 0.480 m. In the report, +6.00 nC and −3.00 nC at 0.120 m give 1.125 × 10⁻⁵ N: right on A, left on B.
5 nC and 4 nC at 0.20 m give 4.5 × 10⁻⁶ N, which is 0.0000045 N—not 0.0045 N. Exponent checks prevent a thousandfold error.
7. Scope
AP Physics 2 topic 10.1 and Cambridge A Level 9702 topic 18.3 cover the quantitative point-charge law. All tasks here use two charges and their mutual forces; forces from several sources require vector addition in the next field work.
✓ Crest’s Checklist
- I use C and m with the SI constant.
- I convert before squaring separation.
- I report nonnegative magnitude.
- I assign direction from signs and geometry.
- I rearrange with a positive square root.
- I check exponents and model assumptions.
— Crest ☆ “Convert to SI, calculate a magnitude, then assign each force direction.”
Mission 9.8 Complete! · All 10 levels cleared · PHYSICS CREST
★ Coulomb’s Law Calculations Master
Convert each input before calculating, then report magnitude and direction as distinct information.