Skip to lesson
PC

PHYSICS CREST

Global Physics Academy

Mission 7.4 · Pressure Gauges Identify the instrument’s reference and the column sign.
Journey Tracker
Progress
0/10
1

WONDER — The Mystery

A Zero Reading Is Not Always a Vacuum

A differential gauge reads zero when its two connected pressures match. An absolute-pressure instrument instead references vacuum. How can a zero atmospheric-gauge reading coexist with a nonzero absolute pressure? How can a liquid column compare pressures above or below atmosphere?

Instrument-reference modelGas connected on leftKnown reference on rightRead the instrument typegasref.
Given conditions only; arrows and distances are schematic.

Model: Static readings use hydrostatic equilibrium and a stated reference. A gauge reading is a signed pressure difference; an absolute instrument uses a vacuum reference. Not every pressure instrument reads atmospheric gauge pressure. U-tube examples have equal-area arms, negligible gas density and capillary effects, and one uniform manometer liquid. The live transient additionally includes stated inertia and damping; height alone measures static pressure only after settling.

2

PREDICT — Commit to Your Answer

DOK 2 — Predict

An explicitly atmospheric-gauge instrument reads −12.0 kPa while its atmospheric reference is 98.0 kPa absolute. What is the measured gas’s absolute pressure?

Signed-gauge givensGauge reading: −12.0 kPaReference: 98.0 kPa absgasref.
Given conditions only; arrows and distances are schematic.

Commit to both a prediction and a reason before revealing the explanation.

Step 1: Pick your answer.

STOP! Before revealing — why did you pick that?

3

▶ PLAY — Live U-Tube: Pressure Step and Settling Columns

DOK 2 — Investigate

Predict, measure and compare

Complete two runs with different gas gauge-pressure steps but the same liquid density and atmosphere. Then change only density from one of that pair. Watch the two liquid levels move in opposite directions and settle. Compare the imposed gauge difference with the height-based static estimate during motion and near rest.

Left arm connects to regulated gas; right arm to atmosphere. The uniform liquid occupies an equal-area U-tube with effective moving length ℓ = 1.6 m. g = 9.8 m/s². At t = 0 a signed gas-pressure step is applied while the liquid is initially level and at rest. Fluid inertia and a supplied linear resistance produce critical damping: ωn = √(2g/ℓ), with damping rate 2ωn. Left downward displacement x follows x = xeq[1 − (1 + ωn t)e^(−ωn t)], where xeq = ΔP/(2ρg). Right level rises by the same x, conserving liquid volume. The measurement is 4 physical seconds over 8 real seconds and ends nearly settled, not at an artificially clamped exact equilibrium. Height difference is 2x; during motion ρg(2x) differs from imposed ΔP because inertia and resistance also balance force. The scale is 300 pixels/m. Damping is explicitly included in this instrument model, unlike an ideal zero-viscosity flow model.

Use the labelled readouts.

Status: Ready

Playback: 8 real seconds per run; read elapsed physical model time. Pause or Step for measurements.

Imposed Gauge Pressure and Static Height Estimate

Use the labelled readouts.

Measurements

Physical elapsed time:
Imposed signed gas gauge pressure:
Gas absolute pressure:
Atmospheric absolute reference:
Right-minus-left liquid height:
Predicted equilibrium height difference:
Height-based static pressure estimate:
Imposed pressure minus static estimate:
Signed left downward liquid velocity:

Load givens — then predict and run

Loading a setup earns no trial credit.

4

♢ DISCOVER — References, Heights, Signs and Units

DOK 1 — Recall

Flip all 4 rule cards. Keep the quantities and model conditions clear.

Rule 1

Identify the instrument

Click to flip

Identify the instrument

An atmospheric gauge reads Pgas − Patm. An absolute instrument references vacuum. A differential instrument compares its two specified connections. A reading’s reference cannot be inferred from the word “instrument” alone.

Rule 2

Signed U-tube difference

Click to flip

Signed U-tube difference

At static equilibrium, Pgas − Preference = ρg(zreference − zgas). Gas pushing its connected level lower gives positive gauge pressure. Its connected level higher gives negative gauge pressure. Use the difference between levels, not one arm’s movement.

Rule 3

Barometer boundary pressure

Click to flip

Barometer boundary pressure

For a static column, Patm = Ptop + ρgh. A near-vacuum top gives the usual approximation Patm ≈ ρgh; trapped gas or vapor pressure can supply a nonzero top correction. Height is vertical.

∫

Rule 4

Height is not automatically a pressure unit

Click to flip

Height is not automatically a pressure unit

A liquid-column height in mm is a length. mmHg is a pressure unit, approximately 133.3 Pa per mmHg. A 180 mm water or oil column cannot simply be relabeled 180 mmHg. Use density, g and height to find pressure first.

Flip all 4 cards to reveal the rules. 0/4 flipped
5

MISCONCEPTION ATTACK — Destroy the Myths

DOK 2 — Analyze

Choose TRUE or FALSE for each claim. The explanation appears after an attempt; only a correct answer completes the claim.

Myth 1: “Every pressure instrument reports pressure above atmosphere.”

Myth 2: “Any liquid column 760 mm high equals one atmosphere.”

6

✦ THE SECOND “AHA!” — Signed Readings and Instrument Boundaries

DOK 2 — Apply

Use the stated reference rather than assuming every gauge has the same type or sign.

Progress
0/4
Instrument-reference modelGas connected on leftKnown reference on rightRead the instrument typegasref.
Given conditions only; arrows and distances are schematic.

1

Instructor Q1 — Zero Atmospheric-Gauge Reading

An atmospheric gauge reads zero. Which statement follows?

2

Instructor Q2 — Which Side Has More Pressure?

A settled equal-area U-tube has gas on the left and atmosphere on the right. The left liquid level is higher than the right. Which comparison is correct?

3

Instructor Q3 — A Positive Gauge Reading

An atmospheric gauge reads +160 kPa; local atmosphere is 98.0 kPa absolute. Find gas absolute pressure in kPa.

Positive-reading givensGauge: +160 kPaAtmosphere: 98.0 kPagasref.
Given conditions only; arrows and distances are schematic.
kPa
4

Instructor Q4 — A Negative Gauge Reading

An atmospheric gauge reads −8.0 kPa; the reference atmosphere is 100 kPa absolute. Find gas absolute pressure in kPa.

Negative-reading givensGauge: −8.0 kPaAtmosphere: 100 kPagasref.
Given conditions only; arrows and distances are schematic.
kPa
7

✎ PRACTICE — Independent Gauge and Column Cases

DOK 1–3 — Practice
DOK 1 — Routine

Challenge 1: A Reduced-Pressure Chamber

An explicitly atmospheric-gauge sensor on a chamber reads −15.0 kPa. Its atmospheric reference is 98.0 kPa absolute. Find the chamber’s absolute pressure.

Chamber givensGauge: −15.0 kPaAtmosphere: 98.0 kPagasref.
Given conditions only; arrows and distances are schematic.
kPa
DOK 2 — Application

Challenge 2: A Barometer with Residual Gas

A static barometer column has liquid density 13600 kg/m³ and vertical height 0.700 m above its reservoir surface. Trapped gas above the column has absolute pressure 5.00 kPa. Take g = 10 m/s² and neglect capillarity. Find the reservoir atmosphere’s absolute pressure. Then find the column height if the top gas were removed to a perfect-vacuum idealization at the same atmospheric pressure and density.

Barometer givensDensity: 13600 kg/m³Column height: 0.700 mTop absolute: 5.00 kPag: 10 m/s²gasref.
Given conditions only; arrows and distances are schematic.
kPa
m
DOK 3 — Audit & Justify

Challenge 3: Audit a Negative Manometer Reading

A settled equal-area U-tube contains liquid of density 1200 kg/m³. Gas connects to the left arm; the right arm is open to an atmosphere of 96.0 kPa absolute. The left liquid level is 0.180 m above the right. Each arm has shifted 0.090 m from its initial equal level. Take g = 10 m/s² and use 1 mmHg ≈ 133.3 Pa. A report makes the gas gauge reading positive, uses one arm’s 0.090 m travel as the level difference, and labels the liquid’s 180 mm height directly as 180 mmHg. Find signed gas gauge pressure in kPa, gas absolute pressure in kPa and equivalent signed gauge pressure in mmHg. Explain all three errors.

Settled U-tube givensDensity: 1200 kg/m³Left is 0.180 m higherEach arm shift: 0.090 mAtmosphere: 96.0 kPag: 10 m/s²gasref.
Given conditions only; arrows and distances are schematic.
kPa
kPa
mmHg
8

☷ CHALLENGE — Sort the Reference, the Sign and the Units

DOK 2 — Apply

Sort the Reference, the Sign and the Units

Classify each statement by the key instrument-reading decision.

0 / 6 correct

9

TEACH — The Feynman Technique

DOK 3 — Teach

Your Final Mission: Explain why zero on an atmospheric gauge does not mean a vacuum, why a higher gas-side U-tube level means negative gauge pressure, and why millimeters of an arbitrary liquid cannot be called mmHg.

Use simple words and at least three short sentences. This checks effort; compare your physics with the Vault or your teacher.

Type Your Explanation (≥ 3 sentences)

Final reward below

Hidden exam secrets inside — Crest's private notebook.